CaC-202
Calcium Carbide Analyzer
The CaC-202 Calcium Carbide Analyzer is a compact benchtop analyzer capable of assessing the calcium carbide content in mineral samples through gasometric analysis. It delivers rapid results with high precision and excellent reproducibility.
Accesories
| Reference | Description | Minimun quantity |
|---|---|---|
| CAC-202-02 | Vessel – metal crucible for samples | 1 |
| CAC-202-81 | Glass crucible Kitasatos | 1 |
| Cac-202-85 | Magnetic stirrer 51x8 mm with ring | 1 |
| AL-104 | O’Ring 30x3, Kitasatos sealing | 1 |
| CAC-202-104 | Flat gasket 140x110x1mm - metal vessel-crucible for samples | 1 |
Request more information
The compact CaC-202 analyzer determines calcium carbide purity through gasometric analysis. The process involves continuous monitoring of pressure increase caused by the acetylene gas released during the decomposition of calcium carbide in water. Calcium carbide is a grayish solid that reacts exothermically with water to produce calcium hydroxide and acetylene gas.
2 H₂O + CaC₂ (solid) → Ca(OH)₂ + C₂H₂ (gas)
The CaC-202 is a fully automatic and user-friendly device. The sample is placed directly into the reactor. Once loaded, the system seals automatically, adds a fixed amount of water, and continuously monitors the pressure increase caused by the generated acetylene until the final result is obtained. It then performs an automatic cleaning and drying cycle, leaving the unit ready for the next sample.
A user-friendly interface allows easy input of sample data, execution of the analysis, and real-time graphical display and storage of results in a database—greatly simplifying diagnostics and data management.
Technical specifications
| Measurement Range | 0 to 100% CaC₂; 0 – 381.3 L/kg at 1 atm and 25°C |
| Result Expression | % CaC₂ or L/kg |
| Sample Weight | 0.1 g to 30 g (recommended: 15 g) |
| Analysis Time | Programmable: 0 – 45 min (recommended: 7 – 10 min) |
| Max Analysis Pressure | 1250 mbar (Max sensor limit: 1600 mbar) |
| Reactor Temperature | Ambient to 100°C (recommended: 45°C) |
| Accuracy | 1.0% |
| Resolution | 0.1% |
| Reagents | Aluminum standard and sodium hydroxide |
| Operating Temperature | 10°C to 35°C |
| Power Supply | 220 VAC, 50 / 60 Hz, 600 W |
| Pneumatic Pressure | Instrument air, max 4.5 kg/cm² (60 psi) |
| Water Supply | Filtered tap water, 2 – 4 kg/cm² pressure |
| Dimensions | 470 mm (H) x 600 mm (W) x 570 mm (D) |
| Weight | 20 kg |
More equipment of interest